APPROVED DOCUMENT K

 0    58 flashcards    sim
download mp3 print play test yourself
 
Question Answer
approved
What is a approved Document?
start learning
zatwierdzony
Building Regulations
start learning
Przepisy budowlane
protection from impact
Protection from falling, collision and impact
start learning
Ochrona przed uderzeniami
impact
The definition of impact is one thing crashing into or having an affect on another.
start learning
wpływ / zderzenie
ladder
start learning
drabina
loading bays
start learning
strefa załadunku
Vehicle barriers
start learning
Bariery pojazdów
glazing
start learning
szyby
provisions
Additional provisions for glazing in buildings other than dwellings.
start learning
Przepisy
dwellings
Additional provisions for glazing in buildings other than dwellings.
start learning
mieszkaniowe
trapping by doors
trap.
start learning
uwięzienie przez drzwi
pułapka
compliance with the law
start learning
zgodność z prawem
workmanship
start learning
jakość wykonania
Handrail
start learning
Poręcz
helical stair
helical stair = spiral stair
start learning
spiralny schody
noising
start learning
nosek schodów
stair tread
start learning
stopnica
pitch
start learning
kąt nachylenia
rise
start learning
wysokość stopnia
riser
start learning
wysokość stopnia
landing
The width and length of every landing should be at least as great as the smallest width of the flight. (minimum 1 m)
start learning
podest / spocznik
staircase
start learning
klatka schodowa
stair enclosure
start learning
klatka schodowa
flight of stairs
start learning
bieg schodów
straight flight stairs
start learning
Schody jednobiegowe proste
dog-legged stairs
start learning
Schody dwubiegunowe proste
winding stairs
start learning
kręte schody
cantiliver stairs
start learning
schody wspornikowe
timber stairs
start learning
Schody z drewna
going
going = tread
start learning
stopnica
RISER in PRIVATE STAIRS
Rise maximum 220mm. RISE = 150mm- 220mm.
start learning
wysokość stopnia
H = 150mm-220mm
GOING in PRIVATE STAIRS
GOING minimum 220mm. GOING = 220mm- 300mm.
start learning
SZEROKOŚĆ STOPNIA
intended
Private: intended to be used for only one dwelling.
start learning
przeznaczony
assembly
Institutional and assembly: Serving a place where many people gather.
start learning
zgromadzenie
gather
Institutional and assembly: Serving a place where many people gather.
start learning
zbierać
headroom
Minimum headroom= 2m.
start learning
wysokość prześwitu
Institutional and assembly stairs
Maximum rise = 180mm. Minimum going 280.(If the area of a floor of the building is less than 100m2, the going may be reduced to 250mm.)
start learning
Instytucjonalne i zbiorowe schody
Pitch
the maximum pitch for private stair is 42°.
start learning
kąt nachylenia
gangway for seated spectators
The maximum pitch for gangways for seated spectators is 35°.
start learning
Przejście na siedzących widzów
escalator
start learning
schody ruchome
stair well
start learning
dusza schodów
fire escape stairs
start learning
schody ewakuacyjne
dividing flights
A stair in a public building which is wider than 1800mm should be divided into flights which are not wider than 1800mm.
start learning
podzielenie biegu
length of flights
The number of risers in a flight should be limited to 16 if a stair serves an area used as a shop or for assembly purposes.
start learning
długość biegu
lending next to doors
at least 400mm.
start learning
spocznik obok drzwi
cupboard
at least 400mm.
start learning
szafka nad spocznikiem
alternating tread stair
start learning
zmienny stopień
walkways
start learning
chodniki
Handrails for stairs
In all buildings hadrail height should be between 900mm and 1000mm measured to the top of the handrail from the pitch line or floor.
start learning
Poręcze na schodach
guarding
Flights and landings shoul be guarded at the sides (in dewellings) when there is a drop of more than 600mm.
start learning
osłona / ochrona
drop
start learning
spadek
guarding
Single family dwellings:1. Stairs, landings, ramps, edges of internal floors. H= 900mm. 2. External balconies and edges of roof. H= 1100mm.
start learning
osłona / ochrona
suitable handrails for common stairs
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
start learning
odpowiednie porecze dla powszechnych schodów poręcze
formula
The normal relationship between the dimensions of the rise and going is that twice the rise plus the going (2R+G) should be between 550mm and 700mm.
start learning
wzór
2R+G = 550mm -700mm
readily
Flights and landings should be guarded at the sides to a height of 900mm. The construction should be that children will not readily be able to climb the guarding and a 100mm ball cannot pass through any openings in the guarding.
start learning
łatwo
Utility stair
start learning
schody użyteczności publicznej
external stairs
For dwellings, for external tapered stairs that are part of the buildings, the going should be a minimum of 280mm.
start learning
schody zewnętrzne
Width of STAIRS
minimum width of 900mm. Landings should be at least the width and length of the minimum width of the fight. For buildings other than dwellings, each landing should have an unobstructed length of at least 1,200m.
start learning
Szerokość schodów